One port for the app, one for the log
In our electronica 2026 interview, Jonathan explained that ATIRA shows up on a computer as two virtual serial ports. The desktop app uses the first port to send commands to the device over UART and receive its replies. A separate logging tool can open the second port at the same time. That port is read-only and mirrors the bytes travelling in both directions. Watch the ISS interview · Read Binho’s ATIRA overview
What to look for when a command fails
Suppose a desktop app asks a controller board to start a test, but the test never starts. Reproduce the failure with the monitor port open and compare the captured exchange with what you expected. If the command is missing or different, start by checking what the app sends. If the expected command is followed by an error, check what that error means in the device’s firmware. If there’s no reply, check the serial settings, wiring and whether the board is running.
A capture gives the app and firmware teams the same exchange to work from. It also gives them something concrete to compare with a successful run when the fault only happens occasionally.
PUT KNOWLEDGE INTO PRACTICE
Let’s talk about your application.
Buy online in The LAB eShop, or ask ISS for advice and a tailored quotation.
Shop online ↗Request a quote →