Binho ATIRA: What did the device actually receive?

When a gadget fails to do what its app tells it to do, where do you look first? The computer might have sent the wrong instruction. The gadget might have received it and sent back an error. Binho’s ATIRA gives developers a way to watch that conversation and see what actually happened.

In this article
One port for the app, one for the logWhat to look for when a command failsAsk an ISS expert ↗

One port for the app, one for the log

In our electronica 2026 interview, Jonathan explained that ATIRA shows up on a computer as two virtual serial ports. The desktop app uses the first port to send commands to the device over UART and receive its replies. A separate logging tool can open the second port at the same time. That port is read-only and mirrors the bytes travelling in both directions. Watch the ISS interview · Read Binho’s ATIRA overview

What to look for when a command fails

Suppose a desktop app asks a controller board to start a test, but the test never starts. Reproduce the failure with the monitor port open and compare the captured exchange with what you expected. If the command is missing or different, start by checking what the app sends. If the expected command is followed by an error, check what that error means in the device’s firmware. If there’s no reply, check the serial settings, wiring and whether the board is running.

A capture gives the app and firmware teams the same exchange to work from. It also gives them something concrete to compare with a successful run when the fault only happens occasionally.

PUT KNOWLEDGE INTO PRACTICE

Let’s talk about your application.

Buy online in The LAB eShop, or ask ISS for advice and a tailored quotation.

Shop online ↗Request a quote →

Keep exploring.

All insights →
SIGNAL → INSIGHT

Choose the tool. Keep the context.

Why your target, software and workflow belong in the same conversation.

ISS Editorial TeamRead insight ↗
01 → 1000

BPM510: Scaling device programming from 2 to 17 sites

A high-mix line and a high-volume line put different demands on a device programmer. BPM Microsystems’ new BPM510 can start with two programming sites and expand to 17. We spoke with BPM in Munich about scaling capacity and carrying forward existing tooling.

ISS Editorial TeamRead insight ↗
ISS / INSIGHTS

Aardvark vs Promira: Which I2C/SPI Tool Should You Choose?

Choosing between Aardvark and Promira? Compare their capabilities and learn which questions to ask before selecting an I2C/SPI tool for your next project.

ISS Editorial TeamRead insight ↗